iio/gyro/bmg160: Use millidegrees for temperature scale

Standard unit for temperature is millidegrees Celcius, whereas this driver
was reporting in degrees. Fix the scale factor in the driver.

Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Mike Looijmans
2019-03-09 16:55:05 +00:00
committed by Jonathan Cameron
parent 0a8a29be49
commit 40a7198a4a
+3 -3
View File
@@ -582,11 +582,10 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
case IIO_CHAN_INFO_LOW_PASS_FILTER_3DB_FREQUENCY:
return bmg160_get_filter(data, val);
case IIO_CHAN_INFO_SCALE:
*val = 0;
switch (chan->type) {
case IIO_TEMP:
*val2 = 500000;
return IIO_VAL_INT_PLUS_MICRO;
*val = 500;
return IIO_VAL_INT;
case IIO_ANGL_VEL:
{
int i;
@@ -594,6 +593,7 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
for (i = 0; i < ARRAY_SIZE(bmg160_scale_table); ++i) {
if (bmg160_scale_table[i].dps_range ==
data->dps_range) {
*val = 0;
*val2 = bmg160_scale_table[i].scale;
return IIO_VAL_INT_PLUS_MICRO;
}