Documentation: ABI: add sinc1 and sinc5+pf1 filter
Add sinc1 and sinc5+pf1 filter types used for ad4080 device. Include these two options into the filter_type available attribute. Add also the option for filter disabled. Signed-off-by: Antoniu Miclaus <antoniu.miclaus@analog.com> Link: https://patch.msgid.link/20250516082630.8236-11-antoniu.miclaus@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
committed by
Jonathan Cameron
parent
6b31ba1811
commit
1543572fff
@@ -2278,6 +2278,9 @@ Description:
|
||||
Reading returns a list with the possible filter modes. Options
|
||||
for the attribute:
|
||||
|
||||
* "none" - Filter is disabled/bypassed.
|
||||
* "sinc1" - The digital sinc1 filter. Fast 1st
|
||||
conversion time. Poor noise performance.
|
||||
* "sinc3" - The digital sinc3 filter. Moderate 1st
|
||||
conversion time. Good noise performance.
|
||||
* "sinc4" - Sinc 4. Excellent noise performance. Long
|
||||
@@ -2293,6 +2296,7 @@ Description:
|
||||
* "sinc3+pf2" - Sinc3 + device specific Post Filter 2.
|
||||
* "sinc3+pf3" - Sinc3 + device specific Post Filter 3.
|
||||
* "sinc3+pf4" - Sinc3 + device specific Post Filter 4.
|
||||
* "sinc5+pf1" - Sinc5 + device specific Post Filter 1.
|
||||
* "wideband" - filter with wideband low ripple passband
|
||||
and sharp transition band.
|
||||
|
||||
|
||||
Reference in New Issue
Block a user