staging: comedi: amplc_dio200_common: 'stopcount' is always 'stop_arg'
When the cmd->stop_src == TRIG_COUNT, the 'stopcount' is the cmd->stop_arg. When the stop_src == TRIG_NONE the 'stopcount' is 0, which is also the cmd->stop_arg. Simplify the 'stopcount' initialization. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
committed by
Greg Kroah-Hartman
parent
75d756e9f0
commit
06f55bb778
@@ -441,13 +441,9 @@ static int dio200_subdev_intr_cmd(struct comedi_device *dev,
|
||||
int event = 0;
|
||||
|
||||
spin_lock_irqsave(&subpriv->spinlock, flags);
|
||||
subpriv->active = true;
|
||||
|
||||
/* Set up end of acquisition. */
|
||||
if (cmd->stop_src == TRIG_COUNT)
|
||||
subpriv->stopcount = cmd->stop_arg;
|
||||
else /* TRIG_NONE */
|
||||
subpriv->stopcount = 0;
|
||||
subpriv->active = true;
|
||||
subpriv->stopcount = cmd->stop_arg;
|
||||
|
||||
if (cmd->start_src == TRIG_INT)
|
||||
s->async->inttrig = dio200_inttrig_start_intr;
|
||||
|
||||
Reference in New Issue