@@ -0,0 +1,42 @@
|
||||
=====================================================================
|
||||
Platform Profile Selection (e.g. /sys/firmware/acpi/platform_profile)
|
||||
=====================================================================
|
||||
|
||||
On modern systems the platform performance, temperature, fan and other
|
||||
hardware related characteristics are often dynamically configurable. The
|
||||
platform configuration is often automatically adjusted to the current
|
||||
conditions by some automatic mechanism (which may very well live outside
|
||||
the kernel).
|
||||
|
||||
These auto platform adjustment mechanisms often can be configured with
|
||||
one of several platform profiles, with either a bias towards low power
|
||||
operation or towards performance.
|
||||
|
||||
The purpose of the platform_profile attribute is to offer a generic sysfs
|
||||
API for selecting the platform profile of these automatic mechanisms.
|
||||
|
||||
Note that this API is only for selecting the platform profile, it is
|
||||
NOT a goal of this API to allow monitoring the resulting performance
|
||||
characteristics. Monitoring performance is best done with device/vendor
|
||||
specific tools such as e.g. turbostat.
|
||||
|
||||
Specifically when selecting a high performance profile the actual achieved
|
||||
performance may be limited by various factors such as: the heat generated
|
||||
by other components, room temperature, free air flow at the bottom of a
|
||||
laptop, etc. It is explicitly NOT a goal of this API to let userspace know
|
||||
about any sub-optimal conditions which are impeding reaching the requested
|
||||
performance level.
|
||||
|
||||
Since numbers on their own cannot represent the multiple variables that a
|
||||
profile will adjust (power consumption, heat generation, etc) this API
|
||||
uses strings to describe the various profiles. To make sure that userspace
|
||||
gets a consistent experience the sysfs-platform_profile ABI document defines
|
||||
a fixed set of profile names. Drivers *must* map their internal profile
|
||||
representation onto this fixed set.
|
||||
|
||||
If there is no good match when mapping then a new profile name may be
|
||||
added. Drivers which wish to introduce new profile names must:
|
||||
|
||||
1. Explain why the existing profile names canot be used.
|
||||
2. Add the new profile name, along with a clear description of the
|
||||
expected behaviour, to the sysfs-platform_profile ABI documentation.
|
||||
Reference in New Issue